I-7540D-MTCP

I-7540D-MTCP ~NEW~ CAN to Ethernet/ Modubs TCP/ Modbus RTU Converter

Artikelnummer
I-7540D-MTCP
Hersteller
ICP DAS
Gewerbliche Kunden: Preis bitte anfragen
Shopbestellung nach Registrierung möglich.
Wenn Sie keine Preise sehen, lassen Sie sich bitte vom Kundensupport die Reseller-Preise freischalten.


 Jetzt anfragen!

The I-7540D-MTCP is helpful for data exchanging between the Modbus devices and CAN devices. I-7540D-MTCP is a Modbus TCP server and acts as slave device in Modbus RTU network. It supports four communication modes: Modbus TCP, Modbus RTU, CAN-Ethernet Convert and Pair connection.
The major function of the I-7540D-MTCP is CAN to Modbus TCP/RTU gateway. It allows Modbus TCP/RTU device to communicate with CAN device on a CAN network. I-7540D-MTCP supports the function codes 0x03/0x04/0x10 of Modbus TCP/RTU for reading and writing CAN messages.
Furthermore, The device supports a transparent, protocol-independent transfer of the CAN messages, thus allowing its implementation into a wide range of possible applications. Furthermore, the CAN-Modbus Convertercan be used with various higher layer CAN protocols (e.g. CANopen, DeviceNet or other proprietary protocols). The following figure shows the application architecture for CAN-Modbus Converter.

 
•Factory Automation    
•Building Automation    
•Home Automation    
•Control System    
•Monitor System
•Vehicle Automation
 

The PM-213x-CAN series power meter provides the CAN bus interface for users to easily gather the real-time power consumption information in their CAN applications. The PM-213x-CAN provides the Auto-Response mode which responses messages at regular intervals automatically. It makes the communication more efficient when collecting a lot of remote power information. The polling mode offers the precise information of every step required by the monitors. In addition, the PM-213x-CAN also owns the arbitration mechanism which can avoid data collision and error detection.

Features of CAN bus power meter:
  • NXP TJA1042 CAN transceiver
  • Follow CiA CAN 2.0B specification
  • Support Auto-Response mode and Polling mode
  • Support baud rate 125 kbps, 250 kbps and 500 kbps
  • Support up to 255 nodes on the CAN network
  • 2500 Vrms isolation on CAN port
  • 4 kV ESD protection on CAN port
  • CAN bus provides better capability in noise suppression
  • Support arbitration mechanism to avoid collision
  • Support error detection and error correction on CAN bus
 
  • 80186-80 Embedded CPU, or compatible
  • Ethernet Protocols, TCP,UDP,IP,ICMP,ARP
  • COM driver support interrupt & 1K QUEUE Input & Output buffer
  • Provide 200 CAN frames buffer in CAN to Modbus Mode
  • NXP 82C 250 CAN Transceiver
  • Support both CAN specification 2.0A and 2.0B
  • Max transmission speed up to 1M bps for CAN and 115.2kbps for RS-232 & RS-485
  • Max transmission distance of CAN over 1000m (follow CAN specification)
  • 7-segment LED display to Module IP, RS-232 baud rate, CAN configuration…
  • CAN Error/Tx/Rx LED indicator
  • Software configurable CAN and RS-232 communication parameters
  • Firmware updated from COM1 or Ethernet port
  • Support Web Configuration
  • Support maximum 24 Ethernet clients connection
  • Support function code 0x03/0x04/0x10 of Modbus TCP/RTU command for reading and writing CAN message
  • Provide the transparent communication between the CAN devices via Ethernet
  • Support 30 specific CAN IDs in the Modbus TCP/RTU mode
 
  • Operation mode configuration
  • IP 、 Gateway 、 Mask configuration
  • CAN bus Baud rate configuration
  • CAN BTR0 and BTR1 configuration
  • CAN acceptance filter configuration
  • CAN 2.0A or 2.0B specific selection
  • Error code Responded selection
  • Easy test to transmit/receive CAN messages
  • Easy test to Modbus TCP/Modbus RTU command

 
Test development:
   OS:Windows XP SP 3
   CPU:Intel Core 2 Duo 2.93 GHz
   RAM:2GB
The test is the performance which transfer 8 bytes data frame from CAN to Ethernet (one TCP client).
CAN setting
Transfer frames
Transfer time(ms)
Ethernet setting
Receive frames
Receive time (ms)
The max frames/sec
ASCII command length
2.0A 1Mbps
1,000,000
436,658
100M
1,000,000
436,781
2290
22 B
2.0B 1Mbps
1,000,000
472,153
100M
1,000,000
472,265
2118
27 B

The test is the performance which transfer 8 bytes data frame from Ethernet (one TCP client) to CAN.
CAN setting
Transfer frames
Transfer time (ms)
Ethernet setting
Receive frames
Receive time (ms)
The max frames/sec
ASCII command length
2.0A 1Mbps
1,000,000
446,296
100M
1,000,000
446,574
2241
22 B
2.0B 1Mbps
1,000,000
465,843
100M
1,000,000
466,066
2147
27 B
 
CAN Interface
Controller
NXP SJA1000T with 16 MHz clock
Transceiver
NXP 82C250
Channel number
1
Connector
2-pin screwed terminal block (CAN_L, CAN_H)
Baud Rate (bps)
10 k, 20 k, 50 k, 125 k, 250 k, 500 k, 800 k, 1 M (allow user-defined baud rate)
Isolation
1000 VDC for DC-to-DC, 2500 Vrms for photocoupler
Terminator Resistor
Jumper for 120 Ω terminator resistor
Specification
ISO-11898-2, CAN 2.0A and CAN 2.0B
UART Interface
COM 1
RS-232
COM 1 Connector
5-pin screwed terminal block (TxD, RxD, RTS, CTS, GND )
COM 2
RS-485 (Self-turner inside)
COM 2 Connector
2-pin screwed terminal block (DATA+, DATA-)
Baud Rate (bps)
110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Data bit
7, 8
Stop bit
1
Parity
None, Even, Odd
Ethernet Interface
Controller
10/100Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX)
Connector
RJ-45 with LED indicator
Power
Power supply
Unregulated +10 ~ +30 VDC
Protection
Power reverse polarity protection, Over-voltage brown-out protection
Power Consumption
2.5 W
Mechanism
Installation
DIN-Rail
Dimensions
72mm x 122mm x 33mm (W x L x H)
Environment
Operating Temp.
-25 ~ 75 ℃
Storage Temp.
-30 ~ 80 ℃
Humidity
10 ~ 90% RH, non-condensing
 
I-7540D-MTCP CR
CAN to Ethernet / Modbus TCP / Modbus RTU Converter (RoHS)
 
wall-plug power Adapter/ 110VAC, 60Hz, 3.6W
wall-plug power Adapter/ 220VAC, 50Hz, 3.6W
9-pin Female D-sub & 3-wire CAN bus cable (1M)
7/14 channel Surge Protector