GW-5493 ~ NEW ~ BACnet/IP to Modbus TCP Gateway

Artikelnummer
GW-5493
Hersteller
ICP DAS
Gewerbliche Kunden: Preis bitte anfragen
Shopbestellung nach Registrierung möglich.
Wenn Sie keine Preise sehen, lassen Sie sich bitte vom Kundensupport die Reseller-Preise freischalten.


 Jetzt anfragen!

GW-5493 is a fully configurable universal Modbus RTU to BACnet/IP gateway. The GW-5493 includes BACnet/IP Server and Modbus TCP Client which is used to make Modbus TCP devices accessible on a BACnet network.
BACnet (Building Automation and Control Networking) protocol has been designed specifically to meet the communication needs of building automation and control systems for applications such as heating, ventilating, air-conditioning control…etc.
The GW-5493 contains a large number of BACnet objects (AI, AO, AV, BI, BO, BV, MSI, MSO, MSV) gives you flexibility in mapping Modbus RTU registers to any combination of BACnet objects. Multiple BIBBs (DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM, DS-COV-B…etc.) are supported. All the data transfer is configurable using a standard Web browser.

 
‧Building Automation
‧ Heating, Ventilating, and Air-conditioning Control
‧ Lighting Control
‧ Access Control
‧Fire Detection Systems

General Features

  • Quickly and Cost Effectively integrate networks
  • Provide PWR/Communication Status indication LED
  • Read/Write any standard Modbus register via BACnet
  • No Programming Required
  • Modbus register mapping configured via web interface

BACnet

  • Fully Compliant with BACnet/IP Server
  • Supports up to 200 objects each of types: Analog Input, Analog Output, Analog Value, Binary Input, Binary Output, Binary Value, Multi-State Input, Multi-State Output,
  • BIBB (BACnet Interoperability Building Blocks) Supported: DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B, DS-COV-B, DM-DDB-B, DM-DOB-B, DM-DCC-B, DM-TS-B, DM-UTC-B, DM-RD-B

Modbus TCP

  • Fully User Configurable Modbus TCP Client
  • Supports Modbus coils, input register, holding registers.
  • Supports for Function Code 0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x10, 0x0F.
  • Configured via standard web browser.
  • Provide Modbus network configuration interface
  • Provide BACnet configuration interface.
 

ICP DAD Fieldbus Gateway Comparison Table:

Support Protocol
GW-5492
GW-5493
GW-7228
GW-7433D
I-7231D
I-7232D
BACnet/IP Server
BACnet/IP Server
J1939
CANopen Master
CANopen Slave
CANopen Slave
Modbus RTU Master
Modbus TCP Client
Modbus RTU Slave
Modbus TCP Server/RTU Slave
DCON Master
Modbus RTU Master
Comm.
Interface
RS-232
RS-485
Ethernet
RS-232
Ethernet
RS-232
RS-422
RS-485
RS-232
RS-485
Ethernet
RS-232
RD-485
RS-232
RD-485
Support Protocol
I-7241D
I-7242D
I-7243D
GW-7243D
GW-7552
GW-7553
DeviceNet Slave
DeviceNet Slave
DeviceNet Master
DeviceNet Slave
PROFIBUS DP-V0 Slave
PROFIBUS DP-V0 Slave
DCON Master
Modbus RTU Master
Modbus TCP Server
Modubs TCP / RTU / ASCII Master
Modubs RTU/ASCII Master/Slave
Modbus TCP / RTU/ ASCII Maste / Slave
Comm.
Interface
RS-232
RD-485
RS-232
RD-485
Ethernet
RS-232
RS-422
RS-485
RS-232
RD-485
RS-232
RD-485
 
GW-5493
BACnet/IP to Modbus TCP Gateway

Nach oben