DeviceNet to DCON Gateway, with 5-Segment Indicat

I-7241D, DeviceNet / DCON Gateway

Artikelnummer
I-7241D
Hersteller
ICP DAS
Gewerbliche Kunden: Preis bitte anfragen
Shopbestellung nach Registrierung möglich.
Wenn Sie keine Preise sehen, lassen Sie sich bitte vom Kundensupport die Reseller-Preise freischalten.


 Jetzt anfragen!

The I-7241D is one of CAN bus products in ICP DAS. The device offers the communication gateway between DeviceNet and DCON protocol. DCON protocol is the communication protocol of I-7K and I-87K series IO modules of ICP DAS. And the I-7241D can be a DeviceNet slave device in CAN bus for DeviceNet network. It is a Group 2 Only Slave device, and supports “Predefined Master/slave Connection Set”. In addition, we also provide the utility software for users to configure the device parameters and build EDS file for the DeviceNet slave device. Users can easily apply I-7k and I-87K IO modules in DeviceNet applications with the I-7241D.

• Control System• Building Automation• Factory Automation• Distributed data acquisition
  • NMT: Slave
  • Support Predefined Master/slave Connection Set
  • Dynamic Assembly Objects Mapping
  • Support Offline Connection Set, Device Heartbeat message and Device Shutdown message
  • Provide Assembly object
  • Dynamic Product EDS File
  • I/O operating modes: Polling, Bit-Strobe, Change of State/Cyclic
  • Support max 15 I-7K/I-87K IO modules
  • Explicit & I/O length: 240 bytes max.
  • Provide friendly Utility to configure
  • Baud Rate: 125Kb, 250Kb, 500Kb
  • On-line change baud rate and MAC ID of CAN
  • 7-segmemt LED to show operation mode, MAC ID, baud rate and error code
   

The I-7241D Utility is help users to configure the modules, and has following features:

  • Support auto-scan I-7K/I-87K modules
  • Auto-scan I-7k/I-87K modules connected with I-7241D COM Port
  • Show I-7k/I-87K modules configuration
  • Show Application and Assembly Objects configuration
  • Support IO connection path setting
  • Support EDS file creating

The simple steps about how to use DNS_DCON gateway are described as follows:


 
Hardware
Watchdog
Watchdog IC
CAN Interface
Controller
NXP SJA1000T with 16 MHz clock
Transceiver
NXP 82C250
Connector
5-pin screwed terminal block (CAN_L, CAN_H, N/A for others)
Isolation
1000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Terminator Resistor
Jumper for 120 Ω terminator resistor
Protocol
DeviceNet Volumn I ver2.0, Volumn II ver2.0
UART Interface
COM 1
RS-232 (For configuration)
COM 2
RS-485 (Self-turner inside)
Transmission Distance (m)
Depend on baud rate (for example, max. 1200 m at 9.6 kbps )
Baud Rate (bps)
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Protocol
DCON
LED
Round LED
MS LED, NS LED, IO LED
5-digit 7 Segment
Yes
Power
Power supply
Unregulated +10 ~ +30 VDC
Protection
Power reverse polarity protection, Over-voltage brown-out protection
Power Consumption
3W
Mechanism
Dimensions
72mm x 122mm x 33mm (W x L x H)
Environment
Operating Temp.
-25 ~ 75 ℃
Storage Temp.
-30 ~ 80 ℃
Humidity
10 ~ 90% RH, non-condensing
 

I-7241D-G
DeviceNet Slave / DCON Master Gateway
I-7241D-G CR
DeviceNet Slave / DCON Master Gateway (RoHS)